Sign In
 
Search
Print Blog   Get Connected  
Bookmark and Share
F-24-C Series Concealed Vertical Rod Fire Exit Device
WP_5852_590x332
OverviewOptionsAccessoriesDownloads

Fire Exit Hardware
The Falcon F-24-C Series device lets you combine the safety of a fire-rated device with the clean aesthetics that come with a narrow stile and concealed vertical rod installation. In-field adjustment is simple thanks to our patented center slide mechanism. Two-point latching ensures optimal security at the door.
 
Features and Benefits
  • Streamlined design includes flush-end cap for clean lines and a more attractive installation
  • Stainless steel pushpad cover for a scratch-resistant surface
  • Clean design with no exposed screws or rivets on the back of the device
  • Patent-pending deadlocking technology ensures reliable security
  • One trim input design for maximum versatility
  • Extruded aluminum construction delivers greater strength and impact resistance
Specifications
  • Hand: Field reversible or specify handing
  • UL: “A” Label (3 Hr) - 8’ x 10’ ; 90 min. same egress - 8’ x 10’
  • Wood Door: 20 min. 8’ x 9’ ; 90 min. 8’ x 8’. Consult door manufacturer for maximum rating. Edge channel may be required.
  • Functions: Delta trim only
  • Finishes: US3 (605); US4 (606); US10 (612); US26 (625); US26D (626); US32 (629); US32D (630); US28 (628), 313AN
  • Strikes: 4188 mortised top, 2130 flush strike bottom
  • Latchbolt: Top stainless steel, 3⁄4” throw. Bottom bolt 1⁄2” throw.
  • Deadlocking Latchbolt: Standard on top latch
  • Latch Retention Hold: Standard in top latch
  • Stock Sizes: See chart below
  • Doors: 1 3⁄4” thick metal. Specify if other than 1 3⁄4” thick.
  • Projection: 2 3⁄4” maximum
  • Stile: 2 1⁄4” minimum when used in pairs (6” minimum on wood doors)
  • Electric Function: Can be interfaced with building security systems. Latch retraction, security monitoring, electric dogging, delayed egress and exit alarm available (EL and ED fail- secure only). Subject to code requirements, state and local
  • Fasteners: All mounting screws are concealed. All machine screws standard.
  • Sex Bolts: Required when used with wood, composite or non-reinforced hollow metal doors. For EO device specify 2 - 425 (#10-24) SNB and 2 - 325 (1/4-20) SNB. For devices with trim, specify 2 - 425 (#10-24) SNB.
  • ANSI: Certified ANSI A156.3-2001 Grade 1 standards
  • F-24-C-LBR: Less bottom rod concealed vertical device. “A” Label (3 Hr) - 8’ x 8’; 90 min. same egress - 8’ x 8’
  • F-24-C-WDC-LBR: Less bottom rod concealed vertical device. Wood Door: 90 minute minimum - 8’ x 8’ openings. Consult door manufacturer for maximum rating. Edge channel may be required.
  • Vertical Rods: Furnished to length based on 40” horizontal CL to finished floor and a 7’0” door. Variations from these standards must be specified when ordering.
  • Patented Centerslide: For ease of adjustment
  • Shim Kit: Consult factory
Device
Door Size
Door Strike
Min Stile (in)
Min Door Opening Width
F-24-C
3'
all
2 1/4"
2' 7 3/8"
F-24-C
4'
all
2 1/4"
3' 1 3/8"
Trim
Function
Function
Function
Function
Lock/Unlock
NL
DT
BE
C
Lever* (712) 
712L
712L-NL
712L-DT
712L-BE
Knob (711)
711K
711K-NL
711K-DT
711K-BE
Delta (717)
--
--
717DT
--
Delta (718)
--
718NL
718DT
--
718C
Athena (715)
--
--
715DT
* Specify hand.
 
24 Series Finishes
 
Color
US Number
BHMA Number
Brass, Bright
US3
605
Brass, Satin
US4
606
Bronze, Satin
US10
612
Chromium, Bright
US26
625
Chromium, Satin
US26D
626
Anodized Aluminum
US28
628
Stainless Steel, Bright
US32
629
Stainless Steel, Satin
US32D
630
Anodized Duranodic
313AN
710
 
24 Series Types and Functions
 
Rim Devices ANSI Type 4
Vertical Rod Devices ANSI Type 5
Concealed Vertical Rod Devices ANSI Type 6
Functions (ANSI)
(F)-24-R
(F)-24-V
(F)-24-C
EO (01) Exit only, no trim.
24-R-EO
24-V-EO
24-C-EO
DT (02) Entrance by trim when actuating bar is locked down. Note: Fire exit devices cannot be dogged down. Some codes permit electric dogging with fail secure circuitry.
24-R-DT
24-V-DT
24-C-DT
NL (03) Entrance by trim when latchbolt is retracted by key. Key removeable only when locked.
24-R-NL
24-V-NL
24-C-NL
L or K (08) Entrance by know or lever. Key locks or unlocks knob.
24-R-L or K
24-V-L or K
24-C-L or K
L (NL) or K (NL) (09) Entrance by knob or lever only when released by key. Key removable only when locked.
24-R-L or K(NL)
24-V-L or K(NL)
24-C-L or K(NL)
Cylinders
  • Cylinder supplied only when specified
  • Cylinders keyed different
Cylinder Reference
Device Trim Standard Key Cylinder IC Key Cylinder
25 Series Device Cylinder Dogging 985 - 1 1/8" Mortise Cylinder C987 - 1 3/8" Mortise Cylinder (Blocking Ring plus Security collar must equal 1/4" Thick)
25 Series Device Rim & Surface Vertical Cylinder Only (NL-OP) 951 - Rim Cylinder C953 - Rim Cylinder
25 Series Device Mortise Cylinder Only (NL-OP) 986 - 1 1/4" Mortise Cylinder C987 1 3/8" Mortise Cylinder
25 Series Trims L, K, TP, NL 986 - 1 1/4" Mortise Cylinder C987 - 1 3/8" Mortise Cylinder
 
Sex Bolts
425 (#10-24 Thread)
 
Removable Mullion
  • The 2923, 4023, KR4023 and 4423 steel mullions are for use with the 25-R devices on double door openings. Advantage: Increased security and tighter closure. Minimizes door warpage and sag. Regulates the flow of in-and-out traffic.
  • Removable mullions are easily removed and reinstalled for full width access.
  • Rim devices are used on both leaves, attaining a perfectly symmetrical opening
  • The mullion assembly consists of a mullion, top and bottom mounting brackets and a screw pack
  • The F4023 and KRF-4023 fire-rated mullions also include four stabilizer blocks as required for labeled installations
  • Strikes are not furnished with the mullion
  • Mullions may be cut on the job for doors under stock lengths
  • KR Mullions require 1 1/4" mortise cylinder with standard A cam

Mullion Features

  • Mullion fittings – ductile iron
  • F4023, 4023, KRF-4023 and KR-4023- 2" x 3" x height 
  • 4023 – 1 1/2" x 2 1/2" x height
  • Prime coat only
  • 7’ or 8’ door opening standard, other door opening as specified
Door Application
 
Label Doors
Falcon models F-25-R, F-25-M, F-25-C and F-25-V are labeled for use as fire exit hardware.
 
Door Thickness
All device and components supplied for 1 3/4" doors standard. Specify door thickness if other than 1 3/4".
 
(F)25-R Double Door Application
Strike Installed With Min. Stile B*
299 2923 mullion 4 1/8" 3"
299 4023 mullion 4 3/8" 3 1/4"
499-F F-4023 mullion 4 1/2" 3 5/16"
264 2923 mullion 4" 2 7/8"
264 4023 mullion 4 1/4" 3 1/8"
1439 2923 mullion 3 7/8" 2 3/4"
1439 4023 mullion 4 1/8" 3"
1606 2923 mullion 4 1/4" 2 5/8"
1606 4023 mullion 4 1/2" 2 7/8"
1609 Surface 25-V 4" 2 3/8"
 
*Backset to vertical center line on the device
 
Strikes
For Rim Devices
  • 299 - Projection 13/16". Panic device only.
  • 1439 Blade Stop - Projection 1/2". Panic device only.
  • 1606 - Projection 3/8". Panic device only.
  • 1609 - Requires coordinator. Panic device only.
  • 264 - Projection 9/16". Panic device only.
  • 299F - Projection 13/16"
  • 499F - Projection 15/16"
For Surface and Concealed Verical Rod Devices
  • 3788 - Furnished top of (F)25-V
  • 4188  -Top strike for (F)25-C
  • 2130 - (F)25-V and (F)25-C standard bottom strike for grouting into concrete or masonry floor
  • 4155 - Optional strike. Panic device only.
For Mortise Lock Devices
  • 1279 - Closed strike used on single doors and on fire exit hardware doors with coordinator
  • F1280 - Open back strike used on pairs of 1 3/4" doors without astragal or coordinator. Can be used on stock hollow metal doors. F1280 B label (1 1/2 hr.) stainless steel strike available.
  • 1281 - Open back strike for 1 3/4" doors. 8" x 1 1/4" face allow use in mortise lock cutout of stock hollow metal door.
Accessories
 
4215 - Angle bracket for flush transom applications. Does not require elimination of latch retention feature. Accepts 3788 strike for 25-V device.
 
Filler Plates
3721/3722/3723
Steel Filler Plates
3721 Cylindrical Lock Front Filler
3722 Strike Filler - set no. SC for 161 cutout
3723 Mortise Lock Front Filler
3722 Strike Filler - set no. SM for 86 cutout.
 
Surface Vertical Extension Rods
Extension rods are available in 12", 24", and 36" lengths in all finishes. Both ends tapped and all-thread included as connector.
 
Concealed Extension Rods
Extension rods are available in 12", 24", and 36". Both ends have pressed-in, threaded inserts.
 
Electric Dogging
Electric Dogging Feature (ED) - for all 24 Series and 25 Series devices
Our patented Electric Dogging (ED) provides quiet, interruption-free operation. This feature can be used on any touch bar (24 or 25) series to hold latches retracted for push-pull operation and can be added to existing devices. Electric dogging is ideal for a variety of application such as churches, auditoriums, theatres, courtrooms, and anywhere that needs dogging with an electronic control for quiet or uninterrupted operation.
 
Specifications
  • Power transfer or electric hinge recommended, 2-wire, minimum rating 1/2 Amp.
  • Recommended power supply PS861 (minimum output 24 VDC/1 Amp).
UL Listed
  • Panic and fire-rated exit devices
  • Retrofit available
Applications
  • Quiet operation at dogged position
  • Theater, library, courtroom, auditorium, church
  • Retrofit available
    • Includes: Electric Dogging unit, Channel cover, Mounting Screw, Slide plate post assembly, Installation instructions
  • Cannot be used with EA, KOR, or EL
  • ED feature used with fire-rated devices must be tied into fire alarm panel
 
Device Door Size Door Strike Min Stile (in) Min Door Opening Width
ED-25-R 3' 299
264
1439
1606
4"
3 7/8"
3 1/4"
3 5/8"
2' 7 1/2"
2' 7 3/8"
2' 6 3/4"
2' 7 1/8"
ED-25-R 4' 299
264
1439
1606
4"
3 7/8"
3 3/4"
3 5/8"
3' 1 1/2"
3' 1 3/8"
3' 1 1/4"
3' 1 1/8"
ED-24-R 3' 299
264
1439
1606
3 1/2"
3 3/8"
2 1/4"
2 3/4"
2' 7 1/2"
2' 7 3/8"
2' 6 3/4"
2' 7 1/8"
ED-24-R 4'      
ED-25-V 3' all 3 1/2" 2' 7 1/8"
ED-25-V 4' all 3 1/2" 3' 1 1/8"
ED-24-V 3' all 2 1/8" 2' 7 1/4"
ED-24-V 4' all 2 1/8" 3' 1 1/4"
ED-25-C 3' all 3 1/2" 2' 7 1/8"
ED-25-C 4' all 3 1/2" 3' 1 1/8"
ED-24-C 3' all 2 1/4" 2' 7 3/8"
ED-24-C 4' all 2 1/4" 3' 1 3/8"
ED-25-M 3' all 4 1/2" 2' 7 1/2"
ED-25-M 4' all 4 1/2" 3' 2"
 
Electric Latch Retraction
Electric Latch Retraction (EL) - for all 24 series and 25 series devices
The Electric Latch Retraction (EL) feature provides control of latch retraction by guard or security system, allowing free entrance from outside or trim side of door. The EL system can be activated to hold the latch open momentarily or forextended periods of time, and can be interfaced with automatic doors, card readers, automatic fire alarm systems, etc. The EL application requires the use of the PS873-2 power supply.
 
EL Device Wire Selection Size/Type
 
Run Length
EL Device w/EPT or Door Loop
0-100 ft. 14 gauge standard wire
101-200 ft. 12 gauge standard wire
 
 
Run Length
EL Device w/ Electric Hinge/Pivot
0-75 ft. 14 gauge standard wire
76-150 ft. 12 gauge standard wire
 
 
Wire Selection
Switch Wire Size
1200 ft. max. 18 guage
 
 
Specifications
 
Solenoid 24VDC
Continuous Duty  
Current Inrush
(300 milliseconds)
16 amperes
Current Holding 0.3 ampere
 
  • Solenoid rated for continuous-duty operation with PS873-2 (required power supply).
  • Power transfer hinge or electric power transfer required.
  • Electric Latch Retraction can be used in conjunction with FSA/FSE (Fail Safe/Fail Secure)
  • Security Monitoring (DM, LM, AE, LK) features; EL feature is available on all 24 and 25 Series standard device specifications
Required Power Supply - PS873-2
The series PS873 power supply is designed to operate a wide variety of elecrical products. EL panics reequire 871-2 PCB minimum. The regulated output power is 24VDC @ ampere. Standard input 120VAC  @ 1.0 ampere or 240VAC @ 0.5 ampere available. This power supply is capable of handling the in rush requirements of the device.
 
Enclosure is 10” high x 12 1 / 2 ” wide x 5” deep (254mm x 323mm x127mm), gray with a hinged cover and constructed of heavy 19-gauge steel. Five 1/2” x 3/4” (13mm x 19mm) knockout holes are provided for conduit connection. Terminal block will accept up to 12-gauge wire.
 
Standard Options:
PS873B with battery
PS873FA with fire alarm
 
Optional Circuit Cards
Factory or Field Installed Circuit Cards: 871-2, Two Zone controller provides two inputs and two outputs. Will operate one or two EL exit devices. Use suffix “-2” for factory installed, example PS873-2.
 
873-AO, Auto Operator function coordinates the electric latch retraction of one or two locks or devices, and signals an auto-operator to open a door. Signaling the auto operator can be performed in two methods: by receiving a signal from a monitoring switch that the lock is unlatched, or upon expiration of a time delay triggered by a “AE” type input switch. Use suffix “-AO” for factory installed, example “AE” PS873-AO.
 
873-4TD, Four Zone controller with Time Delay provides four inputs and four outputs with the time delay. Time delay is field selectable from 0 to 75 seconds, in intervals of 5 seconds. Use suffix “-4TD” for factory installed, example PS873-4TD.
 
Note:
Closing normally open dry contact to the PS873-2 power supply will retract latch(es). Opening normally open switch returns latch(es) to locked position.
 
Device
Door Size Door Strike Min Stile (in) Min Door Opening Width
EL-25-R 3' 299
264
1439
1606
4"
3 7/8"
3 1/4"
3 5/8"
2' 9 3/4"
2' 9 5/8"
2' 9"
2' 9 3/8"
EL-25-R 4' 299
264
1439
1606
4"
3 7/8"
3 3/4"
3 5/8"
3' 3 3/4"
3' 3 5/8"
3' 3 1/2"
3' 3 3/8"
EL-24-R 3' 299
264
1439
1606
3 1/2"
3 3/8"
2 1/4"
2 3/4"
2' 9 3/4"
2' 9 5/8"
2' 9"
2' 9 3/8"
EL-24-R 4' 299
264
1439
1606
3 1/2"
3 3/8"
2 3/4"
2 3/4"
3' 3 3/4"
3' 3 5/8"
3' 3 3/8"
3' 3 3/8"
EL-25-V 3' all 3 1/2" 2' 9 3/8"
EL-25-V 4' all 3 1/2" 3' 3 3/8"
EL-24-V 3' all 2 1/8" 2' 9 3/8"
EL-24-V 4' all 2 1/8" 3' 3 3/8"
EL-25-C 3' all 3 1/2" 2' 9 3/8"
EL-25-C 4' all 3 1/2" 3' 3 3/8"
EL-24-C 3' all 2 1/4" 2' 9 5/8"
EL-24-C 4' all 2 1/4" 3' 3 5/8"
EL-25-M 3' all 4 1/2" 2' 9 3/4"
EL-25-M 4' all 4 1/2" 3' 4 1/4"
 
Delayed Egress System Components
Delayed Egress - for all 24 Series and 25 Series
The delayed egress system provides control for limited egress and high security areas which require accident hazard or fire exit hardware.
 
Delayed Egress Function
When the Delayed Egress System is armed, the mag lock(s) will remain secure against attempted override pressure and severe impacts. Ingress requires an operational trim, along with access control input (i.e. card reader, key switch, keypad). The system is required to be tied into local fire alarm system.
 
A complete delayed egress system requires the following components:
DE5101 is used in delayed exit application and is ideal for controlled areas.
  • Key Switch Operator
    • Arm, disarm, reset and bypass the delayed egress system by the mortise cylinder on the dialogue box (1-1/4” mortise cylinder sold separately)
  • LED status indicator
    • Red LED indicates arm. Disarm and alarm status
  • Alarm Horn
    • Depression of the Falcon 24 or 25 AE device touchpad initiates a local alarm of 100 db when armed
Falcon 25 Series device with AE switch
Power supply
PS861 - The series PS861 power supply is designed for electric locking or monitoring on single or double door applications. The output power is field selectable for either 24 VDC @ 1 ampere or 12 VDC @ 2 ampere. Standard input 120 VAC @ 0.6 ampere and 240 VAC @ 3.0 ampere available. The terminal block will accept up to 14 gauge stranded wire.
 
The gray enclosure is 10” x 10” x 4” (254mm x 254mm x 102mm), has a hinged cover, and is constructed of heavy 19 gauge steel. Six 1/2” (13mm) knockout holes are provided for conduit connection.
 
Options include keylock cover or battery backup. The pair of batteries, which are sealed lead acid battery packs, will provide back-up power for three hours at full load or seven hours at half load. Batteries will automatically recharge when failed power is restored.
 
Models:
PS861 Standard supply
PS861K Standard supply with keylock cover
PS861B Battery backup
PS861FA Fire Alarm
PS861BK Battery backup and with keylock cover
PS861BKFA Battery backup and keylock cover with FA board (24VDC only)
 
PS873
 
Power Transfer Hinge or electric Power Transfer
 
Magnetic locks
Schlage electronics 320+, 350+ or 390+ maintains UL Listing.
 
Popular Delayed Egress Diagram
 
 
Device
Door Size Door Strike Min Stile (in) Min Door Opening Width
25-R 3' 299
264
1439
1606
4"
3 7/8"
3 1/4"
3 5/8"
2' 7 1/2"
2' 7 3/8"
2' 6 3/4"
2' 7 1/8"
25-R 4' 299
264
1439
1606
4"
3 7/8"
3 3/4"
3 5/8"
3' 1 1/2"
3' 1 3/8"
3' 1 1/4"
3' 1 1/8"
24-R 3' 299
264
1439
1606
3 1/2"
3 3/8"
2 1/4"
2 3/4"
2' 7 1/2"
2' 7 3/8"
2' 6 3/4"
2' 7 1/8"
24-R 4'
299
264
1439
1606
3 1/2"
3 3/8"
2 3/4"
2 3/4"
3' 1 1/2"
3' 1 3/8"
3' 1 1/8"
3' 1 1/8"
25-C 3' all 3 1/2" 2' 7 1/8"
25-C 4' all 3 1/2" 3' 1 1/8"
24-C 3' all
2 1/4" 2' 7 3/8"
24-C 4' all 2 1/4" 3' 1 3/8"
25-M 3' all 4 1/2" 2' 7 1/2"
25-M 4' all 4 1/2" 3' 2"
 
Electric Lock/Unlock Trim
Electric Lock/Unlock Trim (FSA/FSE) - for 25 Series
The electric lock/unlock (FSA/FSE) feature allows the controlling of trim while still maintaining free egress at all times. The lock/unlock command can be controlled by a security system, fire alarm system, key switch, card reader, push button or touchpad.
 
FSA (Fail Safe–unlocks when power is interrupted) can be used in areas requiring doors to be unlocked due to fire, power failure or emergency situations. (Examples: stairwells, hospitals, fire exits, etc.)
FSE (Fail Secure–locks when power is interrupted) can be used in areas requiring doors to be locked for security reasons and only unlocked when energized by authorized personnel. (Examples: banks, inner-office, etc.) With either feature, authorized personnel can gain access utilizing key by overriding or bypassing electric locking function.
 
Wire Chart
Length of Wire Run (FT.)
24VDC
0.4 AMPS
0-500 18 AWG
501-700 16 AWG
 
Specifications
  • Solenoid rated for continuous duty at 24V DC 0.4 Amps
  • UL Listed devices
  • Device channel is used as conduit on 25 Series devices
  • Power transfer (EPT-2) hinge 2-wire minimum rated 1/2 Amp
Note:
1. FSA/FSE can be used on all devices.
2. The FSA/FSE feature can be used in conjunction with EL (Electric Latch Retraction), EA (Exit Alarm), Security Monitoring (DM, LM, AE, LK), and ED (Electric Dogging)
 
Minimum Power Supply- PS861
  • PS861 is a power supply unit for FSA/FSE features requiring 115V/60HZ/6 Amp service and control wiring to device
  • PS861 will operate up to 2 devices either simultaneously with one switch, or independently with two switches. 24V DC 1 Amp output from PS861
Note:
PS861 comes in a 10” x 10” x 4” NEMA rated box
 
Exit Alarm
Exit Alarm (EA) - for all 24 Series and 25 Series devices
The Exit Alarm feature provides a battery powered exit alarm to allow for a simple and effective means of monitoring the use of exits while still maintaining means of egress (for code requirements). Powered by the PS-902 power supply, the exit alarm is now designed to have a 24V DC hardwire input come as a standard feature. When the touchbar is depressed the alarm will sound continuously, indicating that the exit has been engaged. The exit alarm can only be reset by way of a standard 1 1⁄4 mortise cylinder with standard “A” ( 5/16” wide x 3/4” long) cam. The design of the unit will allow the single 9V battery to last for at least six months (on standby mode).
 
Minimum door width required for standard devices
Device
Door Size Door Strike Min Style (in) Min Door Opening Width
EA-25-R
3' 299
264
1439
1606
4"
3 7/8"
3 1/4"
3 5/8"
2' 9 3/4"
2' 9 1/8"
2' 8 3/8"
2' 8 7/8"
EA-25-R
4' 299
264
1439
1606
4"
3 7/8"
3 3/4"
3 5/8"
3' 3 1/4"
3' 3 1/8"
3' 3"
3' 2 7/8"
EA-24-R 3' 299
264
1439
1606
3 1/2"
3 3/8"
2 1/4"
2 3/4"
2' 9 1/4"
2' 9 1/8"
2' 8 1/2"
2' 8 7/8"
EA-24-R
4' 299
264
1439
1606
3 1/2"
3 3/8"
2 3/4"
2 3/4"
3' 3 1/4"
3' 3 1/8"
3' 2 7/8"
3' 2 7/8"
EA-25-V 3' all 3 1/2" 2' 8 7/8"
EA-25-V 4' all 3 1/2" 3' 2 7/8"
ES-24-V 3' all 2 1/8" 2' 8 7/8"
ES-24-V 4' all 2 1/8" 3' 2 7/8"
EA-25-C 3' all 3 1/2" 2' 8 7/8"
EA-25-C 4' all 3 1/2" 3' 2 7/8"
EA-24-C 3' all 2 1/4" 2' 9 1/8"
EA-24-C 4' all 2 1/4" 3' 3 1/8"
EA-25-M 3' all 4 1/2" 2' 9 1/4"
EA-25-M 4' all 4 1/2" 3' 3 3/4"
 
Specifications
  • All solid state circuitry
  • Powered by one 9V alkaline battery (supplied)
  • LED indicator showing armed and unarmed status of alarm
  • LED low battery power indicator
  • 10 second delay (during arming) permitting egress
  • Outside key entry without activating alarm (will not work set up as DM option to activate EA)
  • Works with rim, mortise, concealed, surface vertical rod
  • EAK retrofit kit available for your existing devices
  • Alarm sounds at 110 db level
  • UL listed
  • External Inhibit comes as a standard feature for use with a card reader and allows for remote arming and disarming
  • 24V DC hardwire input now comes as a standard feature; powered by the PS-902 power supply
The EA feature can be used in conjunction with FSA/FSE (Fail Safe/Fail Secure) and Security Monitoring (DM, LM, AE) features
 
Note:
Both EA (Exit Alarm) and EAK (Retrofit Kit) supplied with self-adhesive warning label.
 
Auto Reset Option
The auto-reset option is available in 1 1/2, 3, or 6 minute increments
  • See Price Book for list add
  • To order, add "AR" after EA option (Example: EA-AR3)

Minimum Power supply
Specify PS-902 for use as a 24V power supply

 
Device Monitoring
Device Monitoring - for most 24 series and all 25 series devices*
All of the monitoring features available from Falcon provide total flexibility and will interface with any security system. All monitoring switches are dry contact type and are contained within the device, allowing for tamper-resistant operation. Security monitoring features allow monitoring of devices, latches, authorized egress and locking levers. A key override option is available. All of the security monitoring features can be used in any combination with any other Falcon feature. Consult factory for special applications.

DM, LM, AE, LK Monitoring

  • The DM (Device Monitor) feature monitors full latch projection. If the latchbolt is retracted by use of device, or someone tampers with the latchbolt, the switch is activated sending a signal to controlling areas. In devices with the deadlock feature, the deadlatch status is monitored.
  • The LM (Latch Monitor) feature monitors full latchbolt retraction. When the latchbolt is fully retracted a signal is sent indicating door (or device) opened status.
  • The AE (Authorized Egress) feature monitors the depression of the touch bar or crossbar. Activation of the switch indicates use of a door or that the door is in the dogged condition. This feature is especially useful when used to activate or shunt magnetic locking systems.
  • *LM/DM not available on F-24-R.

Key Override Option (KOR)
The KOR feature allows authorized personnel to override monitoring features on a door by use of a keyed 1 1/8” mortise cylinder with 5/16” wide x 3/4” long standard cam (mortise cylinder not supplied). Activating KOR feature allows any feature to be disabled for daytime use or when desired by key holder. This is a maintained contact switch. KOR is especially useful for turning on or off magnetic locking systems and electric dogging control (at the door).This feature is not available with EA feature, cylinder/standard dogging. To order KOR feature add KOR prefix to device designation.
(Example: KOR-DM-24-R-TP)

Note: Use of these features may require a power transfer hinge (supplied by others) or additional wires in the power transfer hinge needed for application when combined with other electrified features.

 
Electrical Options Summary
Electrical Options Matrix - 24 Series
Option
Electric Dogging Electric Latch Retraction (EL)  Delayed Egress Device Monitor (DM) Latch Monitor (LM) Authorized Egress (AE) Key Override (KOR) Exit Alarm (EA)
Electric Dogging (ED)   X Y Y Y Y X X
Electric Latch Retraction (EL) X   Y Y Y Y X X
Delayed Egress Y Y   Y Y Y Y Y
Device Monitor (DM)* Y Y Y   Y Y Y Y
Latch Monitor (LM)* Y Y Y Y   Y Y Y
Authorized Egress (AE) Y Y Y Y Y   Y Y
Key Override (KOR) X X Y Y Y Y   X
Exit Alarm (EA) X X Y Y Y Y X
 

 *Not available on F-24-R

24/25 Series Catalog 

Falcon Exit Alarm Sell Sheet 

 

Installation Instructions

Device Use with Instr #
24-R   640010_A
F-24-R   640010_A
24-V   640011_B
F-24-V   640011_B
24-V-LBR   640011_B
F-24-V-LBR   640011_B
24-C   640012_B
24-C-LBR   640012_B
F-24-C   640012_B
F-24-C-LBR   640012_B
F-24-WDC-90   640012_B
24-WDC   640061_B
F-24-WDC-20   640061_B
Dummy   640059_A

 

Trim Use with Instr #
715DT   640020_A
717DT   640019_A
711K
711K-BE
711K-DT
711K-NL
712L
712L-BE
712L-DT
712L-NL
24-R / 24-V 23792492
718C
718DT
718NL
24-R / 24-V 23792500
719TL
719TL-BE
24-V 640023_A
710TP
710TP-BE
718TP
718TP-BE
24-R / 24-V 640025_A
717DT
718C
718DT
718NL
24-C 23792518
711K
711K-BE
711K-DT
711K-NL
712L
712L-BE
712L-DT
712L-NL
24-C 23792526
700/900 NL Conversion 24R/24V

 

Auxiliary Use with Instr #
DM/LM (factory install wiring)   640057_A
LM/DM Switch Replacement   640078_A
EA Exit Alarm   640026_B
HWEA Hard Wired Exit Alarm   640027_A
AE Authorized Egress   640028_A
EL Electric Latch Retraction   640029_A
ED Electric Dogging   640030_B
CD Cylinder Dogging   640032_A
GBK shim kit   640049_A
Pushbar Service Replacement   640076_A
HD Hex Dogging Service Replacement   640077_A
Center Case Replacement   640079_A
NL-OP Cylinder Only 24-R / 24-V 640085_A
KOR Key Bypass Switch   640087_A

 

Templates

Metal Products
24 Series Device Device Template
(F)24-R T-1320
(F)24-V and (F)24-V-LBR T-1328
F-24-C and F-24-C-LBR T-1340
24-C and 24-C-LBR T-1341
24-C with Aluminum Door Mounting Bracket T-4332
 
24 Series Device 24 Series Trim Trim Template
(F)24-R and (F)24-V (LBR) 715DT T-2320
(F)24-R and (F)24-V (LBR)

711K
711K-BE
711K-NL
712L
712L-BE
712L-NL
712L-DT

T-2360
(F)24-R and (F)24-V (LBR) 718C
718DT/NL
T-2361
(F)24-R and (F)24-V (LBR) 710TP
710TP-BE
718TP
718TP-BE
T-2325
(F)24-V (LBR) 719TL
719TL-BE
T-2323
(F)24-C 717DT
718DT
718C
718NL
T-2362
(F)24-C 711K 
711K-BE
711K-NL
712L
712L-BE
712L-DT
712L-NL
T-2363
 
24 Series Devices 24 Series Strikes Strike Template
(F)24-R 299/299F (standard) T-3201
(F)24-R 499F (optional with mullion) T-3202
(F)24-R 264 (optional) T-3203
(F)24-R 1439 (optional) T-3204
(F)24-R 1606 (optional) T-3205
(F)24-V and (F)24-V-LBR 4215/3788 Top Strike (standard) T-3032*
(F)24-C and (F)24-C-LBR 4188 Top Strike (standard) T-3034*
(F)24-V and (F)24-C 2130 Bottom Strike (standard) T-3053
(F)24-V
24-C
2126-A Bottom Strike (optional) T-3050
(F)24-V
24-C
4155 Bottom Strike (optional) T-3055
 
*For F-24-V-LBR and F-24-C-LBR applications add template T-5494 for Auxiliary Fire Latch
 
Wood Products
24 Series Device Device Template
(F)24-R W-1320
(F)24-V and (F)24-V-LBR W-1328
F-24-C and F-24-C-LBR with Metal Edge 5" Stile W-1342
F-24-C 90 Minute, and F-24-C-LBR 20 Minute Full Steel Channel Stile Construction W-1352
(F)24-C 20 Minute, Centerslide Preparation W-1380
(F)24-C 20 Minute, Top Latch Preparation W-1382
(F)24-C 20 Minute, Bottom Bolt Preparation W-1383
 
(F)24-R and (F)24-V (LBR) 715DT W-2320
(F)24-R and (F)24-V (LBR) 711K
711K-BE
711K-NL
712L
712L-BE
712L-DT
712L-NL
W-2360
(F)24-R and (F)24-V (LBR) 718C
718DT/NL
W-2361
(F)24-R and (F)24-V (LBR) 710TP
710TP-BE
718TP
718TP-BE
W-2325
(F)24-V (LBR) 719TL
719TL-BE
W-2323
(F)24-C 717DT
718C
718DT
718NL
W-2362
(F)24-C 711K
711K-BE
711K-NL
712L
712L-BE
712L-DT
712L-NL
W-2363
 
24 Series Devices 24 Series Strikes Strike Template
(F)24-R 299/299F (standard) W-3201
(F)24-R 499F (optional with mullion) W-3202
(F)24-R 264 (optional) W-3203
(F)24-R 1439 (optional) W-3204
(F)24-R 1606 (optional) W-3205
(F)24-V and (F)24-V-LBR 4215/3788 Top Strike (standard) W-3032*
(F)24-C and (F)24-C-LBR 4188 Top Strike (standard) W-3034*
(F)24-V and (F)24-C 2130 Bottom Strike (standard) W-3053
(F)24-V
24-C
2126-A Bottom Strike (optional) W-3050
(F)24-V
24-C
4155 Bottom Strike (optional) W-3055
 
*For F-24-V-LBR and F-24-C-LBR applications add template W-5494 for Auxiliary Fire Latch
Next Steps
Have any questions or concerns?
For inquiries or concerns regarding Exit Devices:
 
Customer Care, Sales and Technical Support
877-671-7011
24 Series Options
WP_6028_60x34
Allows for application versatility in high-traffic installations
WP_6029_60x34
For added strength and protection
WP_6030_60x34
Offers the security benefits of two-point latching
WP_5852_60x34
Narrow stile design allows for installation versatility
WP_5852_60x34
Offers strength, durability, and fire-rated performance
Heavy Duty Exits
WP_5852_60x34
Some of the toughest, most reliable performance
WP_5853_60x34
A smart solution for your building design